Awarding Strategies using High-Tec Engineering

FLIR SC6000 Series MWIR Cameras

FLIR SC6000 Series MWIR Science-Grade Cameras

The versatile FLIR SC6000 Series cameras give you high speed and high resolution imagery in a package that’s easy to use yet flexible in configurations for just about any scientific or research application.

FLIR SC6000 Series Infrared Camera Features

  • 640 × 512 resolution cooled InSb detector with 25 or 15 µm pixels for detailed MWIR imagery
  • Flexible interfacing
  • Advanced trigger control
  • Fast frame rates – up to 565 Hz at full resolution

Specifications of FLIR SC6000 Series Infrared Cameras

Model Number

FLIR SC6100

FLIR SC6700

FLIR SC6800

FLIR SC6100 Infrared Camera FLIR SC6725 Infrared Camera FLIR SC6800 thumb

Detector

Detector Type Indium Antimonide (InSb)
Spectral Range 3.0 – 5.0 µm or 1.5 – 5.0 µm MWIR: 3.0 – 5.0 µm or 1.0 – 5.0 µm
LWIR: 7.5 – 10.5 µm
3.0 – 5.0 µm or 1.5 – 5.0 µm
Resolution 640 x 512
Detector Pitch 25 µm 15 µm 25 µm
NETD <20 mK (18 mK typical) MWIR: <20 mK (18 mK typical)
LWIR: <30 mK
<20 mK (18 mK typical)

Electronics / Imaging

Synchronization Modes Genlock; IRIG-B; Sync In, Sync Out
Image Time Stamp Internal IRIG-B Decoder Clock / TSPI Accurate Time Stamp
Integration Time 10 µsec to 687 sec 480 ns to 687 sec
Frame Rate (Full Window) Programmable 0.0015 Hz to 126 Hz Programmable 0.0015 Hz to 565 Hz
Subwindow Mode User-Defined
Max Frame Rate (@ Min Window) 35.112 kHz (64 x 4) 4.175 kHz (16 x 4) 16.4 kHz (640 x 4)
Dynamic Range 14-bit
Digital Data Streaming Simultaneous Gigabit Ethernet and Camera Link Simultaneous Gigabit Ethernet and Camera Link (optional CoaXPress)
Analog Video NTSC, PAL, S-Video, SVGA
Command & Control Gigabit Ethernet, USB, RS-232, Camera Link Gigabit Ethernet, USB, RS-232, Camera Link (optional CoaXPress)

Measurement

Standard Temperature Range -20°C to 350°C MWIR: -20°C to 350°C
LWIR: -20°C to 650°C; Optional 250°C to 2000°C
-20°C to 350°C
Optional Temperature Range Up to 1,500°C
Up to 2,000°C
Accuracy ±2°C or ±2% of reading

General

Operating Temperature Range -20°C to 50° C (-4°F to 122°F)