Thermal Bench Top Test Kits
Infrared Camera and Software Solutions for Saving Time and Resources
Save big and get it right. Replace the risky guesswork of thermocouples and spot pyrometers with a new FLIR Infrared Camera Bench Top Test Kit. FLIR cameras deliver thousands of reliable temperature measurements in every thermographic image. And real-time plotting software lets you chart results fast.
FLIR IR Camera Bench Top Test Kits:
- Choice of FLIR A35sc, A65sc, E40sc, or T430sc thermal camera
- Up to 76,800 accurate temperature measurements per thermal image
- Includes Wide 25°Lens (E and T Series only)
- On-Camera Measurement Analysis (E and T Series only)
- Video Recording and Time vs. Temperature Plotting

FLIR A65/35 Bench Test Thermal Kit Camera
- A65 or A35 thermal camera
- Manual focus 48° on A35 and 45º on A65
- ResearchIR: Real-time image/data logging and plotting software
- Camera tripod adapter for locked-down targeting
- PoE injector (Power over ethernet)

FLIR E40sc Bench Test Thermal Kit Camera
- E40sc thermal camera
- 19,200 pixels/spots per image
- 25° lens in the package
- Measurements down to 200μm
- ResearchIR: Real-time image/data logging and plotting software
- Possible to attach to a tripod.

FLIR T430sc Bench Test Thermal Kit Camera
- T430sc thermal camera
- 76,800 pixels/spots per image
- 25° lens in the package
- Remote and auto focus
- Optional close-up lenses for measurement at 50μm and 100μm exist
- ResearchIR: Real-time image/data logging and plotting software
- Possible to attach to a tripod
Detector | FLIR E40 | FLIR T430sc | FLIR A35/A65 |
![]() | ![]() | ![]() | |
Resolution | 160×120 | 320×240 | 320×256 (A35) 640×512 (A65) |
Sensitivity | <0.07°C @ +30°C / 70 mK | <0.030°C | <0.05°C @ +30°C/50mK |
Accuracy | ±2°C or ±2% of reading | ±5°C (±9°F) or ±5% of reading | |
Temperature Range | -20°C to 650°C 0°C to 650°C | -20°C to 650°C | -25°C to +135°C (-13F to +275°F) -40°C to +550°C (-40°F to +1022°F) |
Built-In Digital Camera | 3.1 MPixel | N/A | |
On-Camera Analysis | Center spot Hot spot Cold Spot 3 Spots Difference temperature [two versions] | Center spot Hot spot Cold spot 3 Spots Difference temperature [two versions] | N/A |
Digital Data Streaming to PC | via USB | Gigabit Ethernet | |
ResearchIR Software Included | Yes | Yes | |
Time vs Temperature Plotting | Yes | ||
Minimum Spot Size | 1.1mm | 560 micron | 100 micron |
*For complete AX5 specifications visit: AX5 Specification Chart