Awarding Strategies using High-Tec Engineering

FLIR T1030sc

From its extraordinarily sensitive HD detector to its portable, flexible design, FLIR built the T1030sc for anyone who needs high thermal sensitivity, fast raw data streaming, and customizable features in a battery-powered, handheld, uncooled LWIR camera. The T1030sc captures images with 786,432 non-contact temperature measurements at 30 frames per second. With the High Speed Interface (HSI) connection, the camera streams lossless HD radiometric imagery at 120 Hz or up to 240 Hz with windowing.

The T1030sc offers a thermal sensitivity of < 20 mK (NETD), more than twice the industry standard, and wide temperature ranges with calibrations up to 2000°C. Its FLIR OSX™Precision HDIR Optical System features an ultrasonic drive, ambient temperature drift compensation, and parasitic radiation protection.

This camera is designed as a stand-alone data collection and analysis real-time radiometric system with full toolset embedded right in the camera. View, acquire, analyze, and share data with FLIR’s ResearchIR Max software, or with MathWorks® MATLAB.

FLIR T1030sc Infrared Camera Features

  • 1024 × 768 LWIR HD detector
  • Thermal sensitivity (NETD) of < 20 mK, more than 2x as sensitive as the industry standard
  • On-camera measurement tools and analytics packed in a portable, battery-powered, ergonomic handheld design
  • Raw high-speed data streaming at 120 Hz, or up to 240 Hz with windowing (NUC Corrected, Digital Counts)
  • Full-frame, lossless radiometric video recording to the camera’s removable SD card
  • Wide object temperature ranges – up to 2000°C – while maintaining accuracy of ±2°C
  • FLIR OSX™ Precision HDIR interchangeable lenses provides high-fidelity imagery and accurate temperature measurements at any focal length
  • Wi-Fi communication simplifies image sharing, remote control and viewing, and quick reporting from the field
  • View, acquire, analyze, and share data with provided FLIR ResearchIR Max software, or MathWorks® MATLAB (sold separately)

FLIR T1030sc Infrared Camera Specifications

Model NumberFLIR T1030sc
Imaging and Optical Data
IR Sensor1024 x 768 pixels
Thermal Sensitivity/NETD< 20 mK at +30°C (+86°F)
Lens Choices12°, 28°, 45°, 50 µm Close-up
Field of View (FOV)28° × 21°
Minimum Focus Distance0.4 m (1.32 ft.)
Spatial Resolution/IFOV0.47 mrad (standard lens)
FocusAuto, continuous auto, manual
Digital Zoom1-8x continuous
Detector TypeFocal Plane Array (FPA), uncooled microbolometer
Image Frequency30 Hz
Spectral Range7.5 – 14 µm
Detector Pitch17 μm
Display4.3 in. wide, 800 × 480 pixel capacitive touch screen
Auto-OrientationAutomatic landscape or portrait
ViewfinderBuilt-in; 800 x 480 pixels
Touch ScreenYes
Image Presentation Modes
Thermal ImageFull color IR image
Visual ImageFull color digital image
MSX®Embosses visual details onto the full resolution thermal image, providing perspective and allowing you to read labels
UltraMaxUnique super-resolution process quadruples pixel count, up to 3.1 MP
Measurement
Object Temperature Range–40°C to +150°C (–40°F to +302°F)
0 to +650°C (+32°F to +1202°F)
+300°C to +2000°C (+572°F to +3632°F)
Accuracy±1°C (±1.8°F) or ±1%  at 25°C for temperatures between 5°C to 150°C.
±2°C (±3.6°F) or ±2% of reading at 25°C for temperatures up to 1200°C
Measurement Analysis
Measurement Tools10 spotmeters, 5+5 areas (boxes, circles) with max./min./average
Measurement PresetsNo measurements, center spot, hot spot, cold spot, User Preset 1, User Preset 2
Emissivity CorrectionVariable from 0.01 to 1.0 or selected from materials list
Measurements CorrectionEmissivity, reflected temperature, relative humidity, atmospheric temperature, object distance, external IR window compensation
Automatic Gain ControlManual, Linear, Histogram
Color PalettesIron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava
Color Alarm (Isotherm)Above/below/interval
Measurement Function AlarmAudible/visual alarms (above/below) on any selected measurement function
Storage of Media
Storage MediaRemovable SD card (Class 10)
Image StorageStandard JPEG, including digital photo and measurement data
Time Lapse15 seconds to 24 hours
File FormatsStandard JPEG, measurement data included
CSQ, measurement data included
Video Recording/Streaming
Time Constant< 10 ms
Frame Rate30 Hz, full window, in camera
120 Hz, full window, with HSI to computer
240 Hz, ½ window with HSI
Radiometric IR-Video RecordingReal-time radiometric recording to SD card
Non-Radiometric IR-Video RecordingH.264 to SD card
Radiometric IR-Video StreamingReal-time radiometric streaming via USB
Non-Radiometric IR-Video StreamingH.264 video using Wi-Fi or USB
Digital Camera
Digital CameraField of View Match: adapts to the IR lens
Video LampBuilt-in LED light
Image Annotations
Voice60 sec (via Bluetooth) stored with the image
TextAdd table. Select between predefined templates
Image DescriptionShort note stored in JPEG exif tag
SketchDraw on thermal/digital photo or add predefined stamps
Separate PC software with extensive report generation
Additional Information
GPS, CompassLocation data, camera direction automatically added to every image
Laser PointerUSB-micro-AB, Bluetooth, Wi-Fi, HDMI
Interfaces> 2.5 hours at 25°C (+68°F)
USB, Connector TypeUSB Micro-AB data transfer to and from PC/Uncompressed colorized video
BatteryRechargeable Li-Ion polymer battery
Battery Operating Time> 2.5 hours at 25°C (+68°F)
Charging SystemIn camera (AC adapter or 12 V from a vehicle) or 2-bay charger
Charging Time2.5 hours to 90% capacity
External Power OperationAC adapter, 90-260 VAC input, 50/60 Hz or 12 V output from a vehicle (cable with standard plug, optional)
Power ManagementAutomatic power-off functionality, user-configurable
Operating Temperature Range-15°C to +50°C (+5°F to +122°F)
Storage Temp. Range-40°C to +70°C (-40 to +158°F)
Weight1.9 kg (4.3 lb.) to 2.1 kg (4.6 lb.), depending upon lens model
Tripod MountingUNC ¼”-20
System Includes:
Infrared camera with lens, Battery (2 each), Battery charger, HDMI-HDMI cable, Hard transport case, Large eyecup, Lens cap, Bluetooth headset, SD card, Neck strap, Power supply including multi-plugs, USB cable Standard A to Mini-B, HSI box, Calibration certificate, FLIR Tools download card, User documentation on CD-ROM, Printed documentation